Info:

nanoproofed logo klein2ab

 

 







 

Awards:
In the years 2014 and 2015 with the German Industry Award "Best of" Award

certificate 70249 02

 
"Top Company" - Certificate 06/2017:

siegel kununu1

 

 

 


 

Services PV Pictures

This is a small excerpt from our successfully completed photovoltaic solar coating projects. In the years 2010 to 2017 alone in the subsequent treatments (after shoring) about 45 MW were treated with our method. Added to this are the serial coating projects.

See on this page:

1. Reference images while working on existing systems after installation

2. Reference images while working on new series modules before installation

3. Measurement records of reference and test equipment from our customers to prove performance improvement

4. DIN standards and test scenarios for our technology

5. Our technology has been tested by the following independent, external institutes

 
1. Reference images while working on existing systems after installation

PV Beschichtung Hartkop

Name: Installation Geflügelmasthof 1
City: County Bad Segeberg
Size: 300 kWp
Manufacturer: Suntech
Specials: --

 

PV Beschichtung Parchim

Name: Installation Geflügelmasthof 2
City: County Parchim
Size: 750 kWp
Manufacturer: Sovello & BP Solar
Specials: --

PV Beschichtung Stubben

Name: Installation Schweinemasthof
City: County Segeberg
Size: 350 kWp
Manufacturer: Sharp
Specials: --

tierzucht

Name: Tierzucht Halle 4, Halle 5, Halle 6, Halle 7
City: County Brandenburg
Size: 300,04 kWp
Manufacturer: Schott
Specials: --

Italien pv park

Name: Free Field Plant Napoli Italia
City: County Italy, near Napoli
Size: 921,6 KWp
Manufacturer: SolarWorld
Specials: --

Name: Installation Halle 2 Satteldachhalle
City: County Bad Segeberg
Size: 75 kWp
Manufacturer: Sharp, Samsung
Specials: --

Frankreich Solarbeschichtung

Name: Pultdachhallen France
City: County Frankreich
Size: 5100 kWp (5,1 MW)
Manufacturer: Suntech
Specials: --

Name: Installation Gewerbehallen Central
City: County Schwerin
Size: 1343 kWp (1,3 MWp)
Manufacturer: Mono und Poly von Sunclass
Specials: --

Frankfurt Oder PV Schutz

Name: Installation Mastanlage
City: County Frankfurt/Oder
Size: 2300 kWp (2,3 MW)
Manufacturer: Luxor Solar
Specials: --

 

2. Reference images while working on new series modules before installation

Bobitz Solarversiegelung

Name: Freiflächenanlage Bobitz
City: County Nordwestmecklenburg
Size: 4800 kWp (4,8 MW)
Manufacturer: Runner Solar
Specials: Seriell-Applikation by automatic self constructed coatingmaschine

solarmaschine2

solarmaschine1

Name: Serienbeschichtung Axsun
City: Coating in our factory before shoring
Size: 1000 kWp (1 MW)
Manufacturer: Axsun Solar
Specials: serial application with automatic coating machine

Solar Container Beschichtungsanlage

Name: Serienbeschichtung AlexSolar
City: Coating in the solar park before shoring
Size: 1800 kWp (1,8 MW)
Manufacturer: Alex Solar
Specials: Serial application with automatic coating machine installed in a mobile container

Nehlsen_o1.jpg

 

Company Nehlsen in 2018: Even after 5 years of coverage time of the solar coating, still with perfect results.

So good that the customer still likes to recommend us today. Press release from 2013 here in the appendix.
politur_n.jpg

From "old" make "new" ...... nanoproofed Special cleaning process for PV modules with heavily burnt-in soiling.

nanoproofed has developed a process that can be used to rebuild solar modules with heavily baked-on soiling.

The result is an optimized earnings situation, which corresponds to the new condition.

The procedure was tested by a "Mobile Flasher" from an external, independent testing company, the company
Suncycle GmbH from Hamburg.

Here you can see First-Solar modules that have been tested with this method in cooperation with "juwi Operations & Maintenance GmbH".

With best results and to the fullest customer satisfaction of the company julist GmbH & Co. KG.

Further information on request.

 

3. Measurement records of reference and test equipment of our customers to prove the performance increase (small excerpt)

 LETAuswertung_02.jpg

Unbeatable: 90% "return" in 4 years on your investment in your own PV solar system

The latest values ​​from our customer EWS GmbH & Co. KG unbeatable. 90% return in 4 years to invest in your own photovoltaic system.

The test plant invested € 2,900 for the coating, carried out by the team of nanoproofed GmbH with the nanoproofed Solar Photokat coating.

Coating was in May 2014.

From May 2014 to May 2016, the investment in the nanoproofed SolarPhotokat coating alone returned the investment of € 2,900.

From May 2016 to May 2018 an additional € 2,795.22 was generated. So altogether 5,710.92 € through the nanoproofed Solar Photokat coating.

Result:
Anyone who owns a PV system by Netzgang before 2012 and has not been coated so far, can escape a lot of income.

All data can be proved with real numbers and real references with contact details of the partners. Just ask us!

Also to be found on Facebook:

https://www.facebook.com/nanoproofed/photos/a.194139860610364/1941382562552743/?type=3&theater

 

 

Krannich_Frankreich_Auswertung_Nanobeschichtung_01.jpg

 

Evaluation of a 5.2 MW turbine from France by Krannich Solar GmbH and Co.KG at the German border. Result: 8% performance increase

And once again it shows that the solar and photovoltaic coating from nanoproofed, the promised performance increases and in PV systems, the investment is profitable after 2-3 years, and the investment through the increase in performance, is balanced and then generated additional revenue ,

Results summarized:
The plant parts left to us for processing ran from the beginning 2% to 16% worse and had 2 - 16% less yield thereby.

We have caught these differences, and vice versa, therefore, increasing the performance of e.g. October 2015 to October 2016 of 5-8%.

In July 2017, the non-coated part of the plant was cleaned and the values ​​have not changed significantly. Therefore, one can assume a pollution level of about 1-2%.

After cleaning, it can be clearly seen that the coated part of the system, due to the self-cleaning effect, resembles the parts of the system. This demonstrates the self-cleaning effect. It is again about 6% between July 2017 and December 2017.

See picture in appendix or you can simply send the complete evaluation. Just a short message to us and then you get the corresponding evaluations, information and contact details by mail.

Also to be found on Facebook:

https://www.facebook.com/nanoproofed/photos/a.194139860610364/1929245963766403/?type=3&theater

 

 

Funktionsnachweis_AnlageRSI_Monat 2016 bis 2018_02a.jpg

 

Another current evaluation of a PV system from RSI Rottaler Solar Invest GmbH with our "nanoproofed protection Solar Photokat" coating.
Up to 9% increase in performance compared to uncoated equipment.

Results summarized:
The parts of the equipment left to us for processing ran from 2% to 8% worse from the beginning and had 2 - 8% less yield thereby.

We have caught these differences, and vice versa, therefore, increasing the performance of e.g. August 2016 to August 2017 by 6-9%

In September / October 2017, the non-coated part of the plant was cleaned and the values ​​have shifted again. Therefore, one can assume a pollution level of about 5-9%.

After cleaning, it can be clearly seen that the coated part of the system, due to the self-cleaning effect, resembles the parts of the system. As a result, the Selbstreinigunsgeffekt is detected. Between November 2017 and May 2018 it is now again 5-9%

See picture in appendix or you can simply send the complete evaluation. Just a short message to us and then you get the corresponding evaluations, information and contact details by mail.

Also to be found on Facebook:

https://www.facebook.com/nanoproofed/photos/a.194139860610364/1923246037699729/?type=3&theater

 

 

Juwi_FF_Nanoproofed_01a.jpg

 

Another evaluation, another PV open space plant from juwi Operations & Maintenance GmbH with our "nanoproofed protection Solar Photokat" coating.

7.5% increase in performance compared to uncoated equipment.

Results summarized:

The plant parts of an open-space plant which were handed over to us for processing were handed over to us for processing on 17.05.2013.

To date, the increase in performance is of course available. Evaluations are carried out by JUWI itself. So far, with best results of 7.5% performance increase on average over the complete years and not just for a few months.

See picture in appendix or you can simply send the complete evaluation. Just a short message to us and then you get the corresponding evaluations, information and contact details by mail.

 

4. DIN standards and test scenarios to prove the function of our technology

DIN EN 1096-5: 2016 

Determination of the self-cleaning behavior of coated glass surfaces

DIN 52980 / ISO 10678

Determination of photocatalytic activity by degradation of methylene blue

ISO 27448 

Determination of the photocatalytic activity by measuring the contact angle

IEC 61215

Humidity / heat test, UV test, temperature change test, humidity / frost test, hail test, all passed!

IEC 61701

Salt mist corrosion protection test, passed without problems!

ISO 15184

Pencil hardness, passed without problems!

ISO 2409

Cross cut test, passed without problems!

 

5. Our technology has been tested by the following independent, external institutes:

- CAN Hamburg (Center of Applied Nanotechnology)

- SGS Institut Fresenius GmbH

- Institut Fraunhofer IST

- Por-Lab, Porphyrin-Laboratories GmbH

- Christian Albrechts Universität zu Kiel

News:

nanoproofed logo klein2b engl
rendite_logo_engl.jpg
 
 
 
Network-Member of:
Netzwerk Energie Effizienz  bmwi logo en mittelstand globalUMFIS Logo Banner
 
Confirmed reliability:

Trusted Shop geprüft
PayPal Zahlungen möglich

 

 IT security monitoring:
it sicherheit logo
logo taskforce 2